Virginia construction code 2015

What building code does Virginia use?

Virginia’s state building codes and regulations are administered through the Virginia Uniform Statewide Building Code (USBC), and its associated standards and regulations for industrialized or modular buildings , manufactured homes and amusement devices.

How are building codes enforced in Virginia?

Enforcement of the USBC is the responsibility of the local government’s building inspections department. The local governing body may charge fees to defray the costs of enforcement and appeals arising from the application of the code . The USBC contains enforcement procedures that must be used by the enforcing agency.

What plumbing code does Virginia use?

2015 Virginia Plumbing Code based on the International Plumbing Code 2015 (IPC 2015)

What NEC code is current in Virginia?

The effective date of the 2015 Virginia Codes is July September 4, 2018. This includes the 2014 National Electrical Code . 2020 NEC was adopted with minimal amendments, effective 11/1/20.

Is drip edge code in Virginia?

A drip edge shall be provided at eaves and gables of shingle roofs. Adjacent pieces of drip edge shall be overlapped a minimum of 2 inches (51 mm). Drip edges shall be mechanically fastened to the roof deck at a maximum of 12 inches (305 mm) o.c. with fasteners as specified in Section R905. 2.5.

Is drip edge required by code in Virginia?

When the state adopted the 2012 Virginia Residential Code VRC, they amended it by deleting the drip edge requirement (R905. 2.8. 5) in paragraph 77 of the amendments. Therefore drip edge is not required for new or replacement shingles on one and two family dwelling.

You might be interested:  Quicken loans construction loans

Do I need a permit to build a shed in Virginia Beach?

In Virginia , you generally do not need a building permit for any shed that is less than 256 sq. That means that you can have a shed that is up to 12×20, or 14×18. In these cases, you don’t need to visit the government offices for a permit .

How deep are water lines in Virginia?

All pipes shall be installed at a minimum depth of thirty-six inches (36″) from established final grade to the top of the pipe . Water pipe shall not be installed at depths exceeding six feet (6′) unless specifically approved by the Participating Utility.

Is a dishwasher air gap required in Virginia?

The water supply for dishwashers shall be protected by an air gap or integral backflow preventer.

Is NFPA 70 the same as NEC?

The National Electrical Code ( NEC ), or NFPA 70 , is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is typically adopted by states and municipalities in an effort to standardize their enforcement of safe electrical practices.

What is the difference between a standard and a code?

One way of looking at the differences between codes and standards is that a code tells you what you need to do, and a standards tells you how to do it. A code may say that a building must have a fire-alarm system. The standard will spell out what kind of system and how it must work.

Is NFPA 70 legal?

While NFPA 70E training is NOT required by law except for contractors to the Department of Energy [10CFR 851.23(a)(14)], meeting OSHA requirements for electrical safety training IS required by law . NFPA 70E helps employers meet the performance requirements of the OSHA standards for electrical safety.